SELIS V2 / alternative-directions

Idea 1 — Thermal environment for surface assets

15 November 2026. One of six ideas; read 00-overview.md first. Source numbers refer to its section 8. Compiled with AI (Claude); not re-checked by a person. "Judgement" marks an assessment.

Product in one line

For a chosen site, asset height and surface orientation, the tool returns time series of absorbed solar flux, infrared flux from the surrounding terrain and sink temperature, with a stated uncertainty, through lunar day, night and shadow periods.

Decision it supports

A thermal engineer sizes radiators, heaters, batteries or an RHU, and chooses where an asset can park or hibernate. Today the engineer starts from a flat-plane assumption or builds a terrain model by hand.

Why now

What exists

Data basis and checks

Type A slice (TRL 3)

CF Function Check
CF1 Terrain-coupled flux model at one site: Sun as a disc, reflected light, infrared from surrounding terrain Surface temperature aggregated to 240 m against Diviner
CF2 Sink temperature for an asset at a user-set height and orientation Cross-check against the published NASA flat-plane and terrain cases [9]; this is a comparison between models, not with measured data
CF3 Uncertainty from terrain clones and regolith property ranges Share of Diviner observations that fall inside the predicted range

Out of the Type A slice: any site on demand, PSR interiors, dust on surfaces, export to thermal analysis tools, coupling with a power model.

Users outside ESA (candidates; none contacted)

Four tests (judgement)

Argonaut Mission 1 payloads and MAGPIE (C findings 3). Next step: a second site, PSR interiors, and use by one payload team.

Risks and unknowns